Question Burner Not Working

I'm fairly new to the power wash field and want to learn how to trouble shoot my own equipment AND fix it, if possilbe. I have a pressure washer unit from out of Dallas with a 16hp Vanguard.

A couple days ago the burner stopped igniting; it just emits lazy, faint clouds of diesel fuel.

Any suggestions?


Raul Montano
Paradigm Pressure Washing
Riverside, Ca
909.856.2916
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
  #2 (permalink)  
Old 11-06-06
Larry L.'s Avatar
PWN TEAM - Moderator Emeritus
 
Join Date: Oct 2000
Location: Arkansas
Posts: 3,873
Larry L. is on a distinguished road
Default

Sounds like a blown transformer,a low charged battery could have done it.


When In Doubt Think It Out
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
  #3 (permalink)  
Old 11-06-06
Dave Ott's Avatar
Registered User
 
Join Date: Feb 2004
Location: Roseville MI.
Posts: 192
Dave Ott
Default

Check the wire going to the wing nut on the battery. They vibrate loose sometimes if this is from who I think it is.


Michigan Exhaust Cleaning
Your First Step in Restaurant Duct Fire Prevention
Web: Michigan Exhaust Cleaning
Dave Ott 586-771-7787
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
  #4 (permalink)  
Old 11-06-06
Registered User
 
Join Date: Jun 2006
Location: Avon Park, Florida
Posts: 14
McMoo is on a distinguished road
Default

I also have a burner that will not fire. I can hear the fan turn but nothing happens . Old beckett model "ADC" oil burner 12V, idea's?
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
  #5 (permalink)  
Old 11-06-06
Registered User
 
Join Date: Nov 2006
Location: Georgia/Tennessee
Posts: 5
Stefabe1 is on a distinguished road
Default Possible burner solutions

Try charging the battery first. Its the easy cheap fix.
You may need to but a small trickle charger to keep the battery in top shape in the future.

If that fails, check your transformer. Hook it up to 12 volts and run a srewdriver sideways across the springs -- does it spark? yes = fine no= replace.

Been running the same machine for 14 years never replaced a transformer yet!

Although, it is time for a new one.

*****************CAUTION*************
The smoke is evident you are tossing large amounts of raw unignited diesel in your burner tube. This equals WOOOMF(say this at the top of your lungs) if it lights with heavy amounts of smoke.

Be careful after charging the battery and trying to ignite the burner. All that raw diesel will ignite at once and flames will discharge. (keep body parts clear).

Let it run if this happens until it burns clear. As long as the flames are contained in the tube.
Keep a fire extinguisher handy!

TTYL
Ben
Super Clean Presure Washing Service
Memphis/Atlanta
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
  #6 (permalink)  
Old 11-07-06
Larry L.'s Avatar
PWN TEAM - Moderator Emeritus
 
Join Date: Oct 2000
Location: Arkansas
Posts: 3,873
Larry L. is on a distinguished road
Default

and run a srewdriver sideways across the springs -


When doing this test make sure and not touch any metal of the screwdriver with your hands.The screwdriver should be long enough to reach from spring to spring,it should be layed on top of one spring and slowly moved into the other spring.If the transformer is still good it will fire before the screwdriver touches the other spring.If its good the spark will be strong and if its bad you will get a weak spark or none at all.
If its good and still not firing the burner you could have electro rod problems,they could be out of ajustment.


When In Doubt Think It Out
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote





Pressure Washer Sales & Service Specialists
Since 1979

A Sponsor of PowerWashNetwork since 2000
www.EasyCleanSystems.com
www.PressureWasherZone.com
www.PowerWashDirect.com
Mark McIntyre 800-292-EASY 916-638-0828
E-mail Mark Click Here

Last edited by Mark; 11-07-06 at 06:50 AM.
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
  #7 (permalink)  
Old 11-07-06
Mark's Avatar
Moderator / Sponsor
 
Join Date: Sep 2000
Location: Sacramento California
Posts: 3,159
Mark is on a distinguished road
Default

Sounds like you have some sound troubleshooting
advice given already.

If your transformer / ignitor has at least 12 volts
going in to it, but you can not see a bright blue
spark jump between the scredriver and the spring
{isee above psot by Larry[/i] you need a new
ignitor / transformer, we can ship you one today.

Here is some general troubleshooting information that
may be useful to you or others,

Compliments of: Hydro Tek.

************************************************** *****





Hydro Tek Pressure Washer Troubleshooting Guide


Power System: Gas or Diesel | Electric Motor

Heating System: Diesel Fired | Natural Gas / Liquid Propane

Pumping System


Probable causes are listed with most likely cause first.

Repairs should be made by qualified technicians only.


Power System: Gasoline or Diesel Driven









































































Problem

Probable Cause

Remedy

Engine will not start or crank over.

Battery dead.

Charge or replace battery, add electrolyte if battery is new

 

Dirty Battery Contacts

Clean connections

 

Battery cables disconnected

Connect or replace damaged cables.

 

Engine, pump, or gearbox is seized.

Replace or repair seized part.

 

Key switch, solenoid or starter on engine defective.

Repair or replace faulty component.

Engine will not start but will crank over

Engine power switch is off or defective.

Check engine power switch.

 

Low oil shut down is activated.

Add oil to engine, check more frequently.

 

Low on fuel.

Fill with the appropriate fuel, bleed injector pump on diesel engines. Bleed injector pump on diesel engines

 

Fuel filter is clogged.

Replace or clean fuel filter, bleed injector pump on diesel engines.

 

Engine flooded or starved.

Choke only as required (not applicable to diesels).

Engine bogs down under load, whenever spray gun is triggered.

Engine needs to be repaired or replaced.

See engine manual or engine dealer.

 

Operating in high elevation.

Lower the pressure on the unit and check for correct engine speed (RPM).

 

Carbon deposits on cylinder head.

Remove head and clean off deposits.


Power System: Electric Driven | Top





















































Problem

Probable Cause

Remedy

Electric motor does not start.

No electric power.

Check cord, plug, socket, and breaker.

 

Thermal overload in the motor/or starter has been tripped.

Reset manual overload by depressing the thermal switch on the outside of the motor or starter after the motor has cooled. CAUTION! Automatic overload will restart the motor automatically when it has cooled.

 

Power switch inoperative.

Check power switch.

 

Electric motor or wiring failure.

Replace or repair motor and/or wiring.

 

No water pressure at inlet

Connect to appropriate water supply

Machine will not auto-start (if equipped)

Must have adequate water supply

25 psi minimum

 

Coil scale build up

Descale coil for better water flow.

 

Check filter screen and inlet pressure

Remove spray nozzle and pull trigger gun to check auto-start function.

 

Inlet flow switch defective or jammed with debris

Check mechanical function and electrical signal to relay by testing for continuity on #2 and #4 of the time delay. If no continuity with the trigger pulled replace inlet flow switch. If continuity is present, remove wires from #1 and #5 of the time delay relay and make connection between the two wires and test the machine. If the machine works replace the time delay relay. If machine does not work check and replace the contactor or motor starter.


Pumping System | Top


















































































































































































Problem

Probable Cause

Remedy

Trigger gun leaks or will not shut off.

Debris in gun valve assembly.

Clean valve assembly or replace gun.

Pump runs but there is no spray pressure.

Water turned off.

Turn water on.

 

Nozzle is plugged.

Clean or replace with proper size.

 

Inlet chemical injection valve is open, without the end of the pickup tube inserted into detergent.

Close soap valve or submerge detergent pickup tube into solution.

  Coil on hot water machines is obstructed. Clean obstruction or scale deposits from coil with coil cleaner.

 

Pump dry, needs to be primed.

Crack open fitting on the high pressure outlet of the pump until water flows out.

Pump runs but has low spray pressure.

Nozzle not installed.

Install proper sized nozzle.

 

Dual wand valve is open.

Dual wand valve must be closed and high pressure nozzle installed.

 

Leaky discharge hose or quick coupler.

Replace hose, quick coupler, or O-ring in the quick coupler.

 

Inlet strainer clogged.

Clean and check more frequently.

 

Worn or wrong size nozzle.

Replace nozzle of proper size.

 

Belt slippage

Tighten or replace with correct belt.

 

Unloader valve worn or improperly adjusted.

Install pressure gauge on pump head to adjust pressure. Check valve seat on Unloader.

 

Air leak in inlet plumbing.

Reseal fittings and inspect inlet hoses for air leaks.

Pump runs but there is erratic, fluctuating pressure.

Inadequate incoming water supply.

Increase water supply flow.

 

Stuck inlet or discharge valves.

Clean out or replace worn valves

 

Restricted inlet or air entering the inlet plumbing on the pump.

Check fittings and hose for air tight seal, clean inlet strainer screen.

 

Leaking H.P. seals.

Replace seals.

 

Leaking L.P. seals.

Pressure feed the pump and replace LP seals if water leaks from the pump head.

Excessive crankshaft play or loud, knocking noise in pump.

Broken or worn bearing or connecting rod in crankcase.

Replace pump or bearing.

Oil leaking from pump.

Loose drain plug or damaged seal.

Locate point of oil leakage and replace damaged O-ring or seal.

Inlet injection will not siphon chemical.

Check valve in strainer clogged.

Clean or replace. Rinse after each use.

 

Chemical valve not open or clogged.

Open chemical valve or clean.

 

Strainer not submerged in solution.

Submerge strainer and replenish chemical.

 

Detergent hose cut or kinked

Inspect hose, replace as necessary.

Water is emitted from the chemical pickup tube

Check valve malfunctioning.

Repair or replace check valve.

Downstream injector will not siphon chemical.

Brass knob on injector is closed.

Open by turning counter clockwise.

 

Unit not in low pressure mode.

Open dual wand or install low pressure tip.

 

Detergent hose cut or kinked.

Inspect hose, replace as required.

 

Strainer plugged or not submerged.

Check screen on strainer pickup tube.

 

Internal injector parts corroded or stuck.

Disassemble, clean or replace.

 

Outlet water temperature too high.

Use with cold water (150º Maximum)

Pressure relief reliving water Unloader failure / coil overheating / Excessive pressure Turn machine off wait a few minutes and restart. If problem continues take to an authorized repair center for complete system check.
Burst disk relieving water Excessive pressure and / or system spikes Take in to an authorized repair center for a complete system check.

Heating Burner System - Diesel Fired | Top








































































































































































Problem

Probable Cause

Remedy

Burner will not fire.

WARNING: High voltage on igniter can cause electrical shock. Disconnect power before servicing.
Burner switch not on. Turn switch on; Thermostat on if equipped.
  Diesel fuel level low. Fill burner tank with #2 diesel or other approved fuel.
  Trigger on spray gun not pulled. Squeeze trigger to fire burner.
  Fuel filter plugged. Clean and / or tighten fuel filter. (Check fuel pressure)
  Spray nozzle plugged. Clean spray nozzle.
  Overload on burner motor tripped. Reset overload, locate and correct source of overload.
  Nozzle not in wand. Install nozzle in wand.
  Low water pump pressure. See pumping systems trouble shooting.
  Fuel pump or nozzle stopped. Check fuel pressure, filter, fuel lines. Replace fuel pump and/or nozzle.
  Vacuum, Flow, Pressure or Temperature switch faulty. Check electrical continuity with pump spraying and burner on.
  Fuel solenoid valve faulty. Replace fuel valve if it does not open when power is applied.
  Low generator voltage output. Adjust generator RPM for proper voltage under full load conditions.
  Burner relay faulty (12-V Burner only) Replace burner relay.
Burner will not fire, plus diesel fumes are emitted from the exhaust port.

WARNING: Replace insulation. Unburned fuel can saturate it and cause a fire.
Fuel to air ratio out of adjustment. Set air band and fuel pressure to specs.
  Fuel nozzle partially clogged. Replace nozzle of proper size.
  Ignition transformer not providing spark to fuel. Replace ignition transformer, clean and adjust electrodes.
Burner fires and smokes. Fuel to air ratio out of adjustment. Set air band and fuel pressure to specs.
  Excessive soot on coils. Clean soot off to improve air flow.
  Improper voltage at burner Adjust RPM of generator (if equipped)
Discharge water temperature exceeds recommended operating temperature. Burner input too high for conditions. Decrease fuel pump pressure and/or fuel nozzle size.
  Water flow restricted. Clean or replace nozzle of proper size. Descale coil and clear obstructions.
  High temperature limit switch faulty or set too high. Replace or reset temperature limit switch.
Burner continues to fire even when trigger on spray gun is released Faulty Flow, Pressure or Vacuum switch. Replace switch.
  Faulty fuel solenoid Replace solenoid
Discharge water temperature not reaching maximum operating temperature. Burner input too low for conditions Increase fuel pump pressure and/or fuel nozzle size.
Battery keeps losing voltage. (For 12 volt burner systems) Battery voltage Low. Have battery checked and load test, charge if low and replace if necessary. Allow water to cool 2 min. before shutting off engine.
  RPM too low. Engine RPM should be 3600 RPM w/no load.
  Engine charging system faulty. Check engine charging system - Must have 16 Amp output.
  Electrodes misadjusted Adjust electrodes to maximum 1/8" gap.
  Fuel pump pressure too high. Fuel pump pressure should be approximately 100 to 110 PSI.
  Air band open too far. Adjust for proper burn.
  Burner amp draw too high. Check amp draw of burner motor - should be 13 amp or less. Check amp draw of transformer should be 4.2 or less.

Heating/Burner System - Natural Gas or Liquid Propane Fired | Top




















































































































































Problem

Probable Cause

Remedy

Pilot will not light, burner will not fire. Burner switch not on. Turn switch on.
  Trigger not pulled. Pull trigger. Burner should fire only when trigger is pulled.
  Gas valve turned off. Turn gas valve on.
  No voltage to valve. Check for 24 VAC between pilot valve(PV) and PV/MV. Valve will operate between 20.5 and 28.5 VAC.
  Pilot orifice plugged. Remove orifice & clean.
  Defective ignition module. Check for 24 VAC incoming @ 24v & 24v ground. (If you get voltage to module, but not through module, replace.)
  Defective transformer Check for 24v output. If no voltage, replace.
  Defective flow switch. Replace.
  Defective thermostat. Replace.
  Faulty rocker switch. Replace.
  Igniter not working. Test for spark. Test for continuity between ignition wire and ground.

WARNING: High voltage igniter can cause electrical shock.
Pilot lights, but burner will not fire. Check for 24 VAC between main valve (MV) and PV/MV. If no VAC @ valve, replace module. If you get voltage, replace valve.
Burner fires, but goes out. Check for continuity between ignition cable and ground wire. Assure good ground.
  Faulty ignition module. Replace module.
  Excess draft. Protect from windy conditions.
NG or LP odor is present.

WARNING: Check all NG / LP connections with soap solution before operation.
Gas leak ahead of valve. Turn gas off. Call gas supplier.
  Lockout not working. Replace module.
  Valve stuck. Turn main gas valve off. Replace valve.
Discharge water temperature to high. Faulty thermostat. Replace.
  Water restriction. Clean or replace spray nozzle, descale coil, remove obstructions.
  Incoming gas pressure to high. Lower gas pressure.
Discharge water temperature not reaching maximum operating temperature. Worn spray nozzle. Replace spray nozzle with proper size.
  Gas pressure too low. Increase gas pressure or install additional jets.
  Draft under burner manifold. Prevent down draft with installation of down draft diverter. Prevent side draft with nonflammable barrier.
Burner continues to fire even when water is not being sprayed. Faulty flow switch. Replace.
  Main gas valve stuck open. Replace main gas valve.
Valve has had water sprayed on it. Has been submerged in water and does not work. Flood or accidental spraying. Replace valve: Do not attempt to repair or clean out.
Ignition module has been subjected to water or moisture. Flood or accidental spraying. Replace module: Do not attempt to repair.

Top  


  #8 (permalink)  
Old 11-07-06
Registered User
 
Join Date: Jun 2006
Location: Avon Park, Florida
Posts: 14
McMoo is on a distinguished road
Default

Thanks!!!!! Ben, Larry And Mark........... I will try all of the above. On the beckett wear is the reset located? Thanks Dan
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
  #9 (permalink)  
Old 11-08-06
ParadigmPW's Avatar
Registered User
 
Join Date: Mar 2005
Location: Riverside, California
Posts: 2
ParadigmPW is on a distinguished road
Default Appreciative!

Thanks or all the input, suggestions and ***CAUTION***.

I've opened up the transformer and done the srewdriver check for an arc and found NONE. I have an appointment to take it into Geyser in Riverside to have it replaced.

I'd want to get to know my machine better and even do some of the fixin myself: HydroTech or another Co., can you give me a quote on a transformer to match up against what I'm being charged tomorrow? Beckett 12V

Thanks again!


Raul Montano
Paradigm Pressure Washing
Riverside, Ca
909.856.2916
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Reply

Bookmarks



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is On
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
Burner problems oneness Equipment Help 12 08-09-03 08:52 PM
Burner Problems???HELP??? B.J. ELLIS Equipment Help 15 04-12-02 06:50 AM
Burner Soot/Smoke on New Unit Paul Freeman Equipment Help 8 03-25-02 12:54 PM
Burner working intermitantly Blown Away Equipment Help 5 03-16-02 09:49 PM
Burner not working Tim Equipment Help 4 04-19-01 06:41 PM

 
 
Sponsored Links